Helium Oxygen Mixture description, usages, side effects, indications, overdosage, supplying and lots more!

Menu
Search

Helium Oxygen Mixture

Airgas Intermountain Inc

helium oxygen mixture




FULL PRESCRIBING INFORMATION


AIRGAS PURITAN MEDICAL Distributed By: Airgas Intermountain, Inc. Denver, CO 80216 (303) 370-7800

COMPRESSED GAS, N.O.S.
(  % HELIUM USP,   % OXYGEN USP)
UN3156
MEDICAL GAS Rx only. Gases used to prepare this mixture meet USP specifications where applicable.
NON-FLAMMABLE 2     OXIDIZER 5.1

CAUTION: Federal law prohibits dispensing without a prescription. WARNING: Administration of this gas may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of gas mixtures, and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications and side effects, and the precautions to be taken.

CAUTION: HIGH PRESSURE OXIDIZING GAS. MIXTURES CONTAINING IN EXCESS OF 23.5% OXYGEN MAY VIGOROUSLY ACCELERATE COMBUSTION. Store and use with adequate ventilation. Keep oil and grease away. Use only with equipment cleaned for oxygen service and rated for cylinder pressure. Use a back flow preventive device in the piping. Cylinder temperature should not exceed 52oC(125oF). Open valve slowly. Close valve after each use and when empty.
    
 FIRST AID:   IF INHALED, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician.     C.A.S. : HELIUM 7440-59-7        OXYGEN 7782-44-7 Use in accordance with the Material Safety Data Sheet (MSDS).

DO NOT REMOVE THIS PRODUCT LABEL.

Form 850402D (R08/04)Helium Oxygen Mixture


COMPRESSED GAS, N.O.S.
(  % HELIUM USP,   % OXYGEN USP)
UN1956
MEDICAL GAS Rx only. Gases used to prepare this mixture meet USP specifications where applicable.
NON-FLAMMABLE 2
AIRGAS PURITAN MEDICAL Distributed By: Airgas Intermountain, Inc. Denver, CO 80216 (303) 370-7800

CAUTION: Federal law prohibits dispensing without a prescription. WARNING: Administration of this gas may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of gas mixtures, and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications and side effects, and the precautions to be taken.

CAUTION: HIGH PRESSURE OXIDIZING GAS. MIXTURES CONTAINING LESS THAN 19.5% OXYGEN MAY CAUSE RAPID SUFFOCATION. Store and use with adequate ventilation. Keep oil and grease away. Use only with equipment cleaned for oxygen service and rated for cylinder pressure. Use a back flow preventive device in the piping. Cylinder temperature should not exceed 52oC(125oF). Open valve slowly. Close valve after each use and when empty.
    
 FIRST AID:   IF INHALED, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician.     C.A.S. : HELIUM 7440-59-7        OXYGEN 7782-44-7 Use in accordance with the Material Safety Data Sheet (MSDS).

DO NOT REMOVE THIS PRODUCT LABEL.

Form 850303 (R08/04)Helium Oxygen Mixture

COMPRESSED GAS, N.O.S.
(  % HELIUM USP,   % OXYGEN USP)
UN3156
NON-FLAMMABLE 2     OXIDIZER 5.1
834499 (12/04)
OXYGEN CONTENT OVER 23.5%
Rx only.
CAUTION: Federal law prohibits dispensing without a prescription. WARNING: Administration of this gas mixture may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of gas mixtures, and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications and side effects, and the precautions to be taken.

CAUTION: HIGH PRESSURE OXIDIZING GAS. VIGOROUSLY ACCELERATES COMBUSTION. Keep oil and grease away. Open valve slowly. Store and use with adequate ventilation. Use only with equipment cleaned for oxygen service and rated for cylinder pressure. Use a back flow preventive device in the piping. Cylinder temperature should not exceed 52oC(125oF). Close valve after each use and when empty. Use in accordance with the Material Safety Data Sheet (MSDS).
    
 FIRST AID:   IF INHALED, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician.     CAS. : OXYGEN 7782-44-7         HELIUM 7440-59-7
DO NOT REMOVE THIS PRODUCT LABEL.

AIRGAS PURITAN MEDICAL Distributed By: Airgas Intermountain, Inc. Denver, CO 80216 (303) 370-7800Helium Oxygen Mixture

COMPRESSED GAS, N.O.S.
(  80% HELIUM USP, 20 % OXYGEN USP)
UN1956
NON-FLAMMABLE 2
837137 (10/07)
Rx only. CAUTION: Federal law prohibits dispensing without a prescription. WARNING: Administration of this gas mixture may be hazardous or contraindicated. For use only by or under the supervision of a licensed practitioner who is experienced in the use and administration of gas mixtures, and is familiar with the indications, effects, dosages, methods, and frequency and duration of administration, and with the hazards, contraindications and side effects, and the precautions to be taken.

CAUTION: HIGH PRESSURE GAS MIXTURES CONTAINING LESS THAN 19.5% OXYGEN MAY CAUSE RAPID SUFFOCATION. Store and use with adequate ventilation. Keep oil and grease away. Use only with equipment cleaned for oxygen service and rated for cylinder pressure. Use a back flow preventive device in the piping. Cylinder temperature should not exceed 52oC(125oF). Open valve slowly. Close valve after each use and when empty. Use in accordance with the Material Safety Data Sheet (MSDS).
    
 FIRST AID:   IF INHALED, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician.  HELIUM CAS: 7440-59-7   OXYGEN CAS: 7782-44-7         
DO NOT REMOVE THIS PRODUCT LABEL.

AIRGAS PURITAN MEDICAL Distributed By: Airgas Intermountain, Inc. Denver, CO 80216 (303) 370-7800Helium Oxygen Mixture

Helium Oxygen Mixture

Helium Oxygen Mixture GAS

Product Information

Product Type Human prescription drug label Item Code (Source) NDC:58420-007
Route of Administration RESPIRATORY (INHALATION) DEA Schedule

Active Ingredient/Active Moiety

Ingredient Name Basis of Strength Strength
Helium Helium 800 mL
Oxygen Oxygen 200 mL

Packaging

# Item Code Package Description Marketing Start Date Marketing End Date
1 NDC:58420-007-01 594 in 1 CYLINDER
2 NDC:58420-007-02 2745 in 1 CYLINDER
3 NDC:58420-007-03 4754 in 1 CYLINDER
4 NDC:58420-007-04 5547 in 1 CYLINDER
5 NDC:58420-007-05 5603 in 1 CYLINDER
6 NDC:58420-007-06 5660 in 1 CYLINDER

Marketing Information

Marketing Category Application Number or Monograph Citation Marketing Start Date Marketing End Date
1998-01-01


PLEASE, BE CAREFUL!
Be sure to consult your doctor before taking any medication!
Copyright © 2014. drugs-library.com. All rights reserved. Information on drugs-library.com is provided for educational purposes only and is not to be used for medical advice, diagnosis or treatment.
Support info@drugs-library.com.