OXYGEN
FULL PRESCRIBING INFORMATION: CONTENTS*
- OXYGEN COMPRESSED LABEL
- OXYGEN REFRIGERATED LABEL
- GENERAL WARNINGS AND PRECAUTIONS
- OXYGEN CERTIFICATE OF ANALYSIS
FULL PRESCRIBING INFORMATION
OXYGEN COMPRESSED LABEL
OXYGEN COMPRESSED UN 1072 OXYGEN U.S.P. WARNING: HIGH PRESSURE OXIDIZING GAS VIROROUSLY ACCELERATES COMBUSTION STORE AND USE WITH ADEQUATE VENTILATION. USE A BACKFLOW DEVICE IN THE PIPING. CYLINDER TEMPERATURE SHOULD NOT EXCEED 52 C (125 F). Keep oil, grease and combustibles away. Open valve slowly Use only with equipment cleaned for oxygen service and rated for cylinder pressure3. User shall secure cylinder in use and in storage. Close valve after each use; and when empty. Keep valve protective cap in place when not in sue, if so equipped. Use in accordance with MSDS. WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications RX only. Uninterrupted use of high concentrations of oxygen over a long duration without monitoring its effect on oxygen content of arterial blood may be harmful. Use only pressure reducing equipment and apparatus designed for oxygen. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction Do not remove this label Made in the USA Rev 1008
OXYGEN REFRIGERATED LABEL
OXYGEN REFRIGERATED LIQUID OXYGEN 2 U.S.P. UN 1073 Gross Wt. ______ Lbs. ______ oz. Net Wt. ________ Lbs. ______ oz. Size ____________ Contents _____ Liters Oxygen produced by Air Liquefaction ALWAYS KEEP CONTAINER IN UPRIGHT POSITION. WARNING EXTREMELY COLD OXIDIZING LIQUID AND GAS UNDER PRESSURE VIGOROUSLY ACCELERATES COMBUSTION. COMBUSTIBLES IN CONTACT WITH LIQUID OXYGEN MAY EXPLODE ON IGNITION OR IMPACT. CAN CAUSE SEVERE FROSTBITE. USE IN ACCORDANCE WITH OXYGEN, REFREGERATED LIQUID MSDS. DO NOT CHANGE OR FORCE FIT CONNECTIONS. USE A BACK FLOW PREVENTATIVE DEVICE IN THE PIPING. CONTAINER TEMPERATURE SHOULD NOT EXCEED 52° C (125° f) Keep oil, grease, and combustibles away. Use only with equipment cleaned for oxygen service. Use only with pressure reducing equipment and apparatus designed for oxygen. Store and use with adequate ventilation. Do not get liquid in eyes, on skin or clothing. For liquid withdrawal, wear face shield and gloves. Don not drop. Use hand truck specifically designed for liquid cylinder movement. Avoid spills. Do not walk on or roll equipment over spills. Close valve after each use and when empty. WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, RX only. Uninterrupted use of high concentrations of oxygen over a long duration without monitoring its effect on oxygen content of arterial blood may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunctions with resuscitative equipment. Keep out of reach of children. In case of frostbite, obtain medical treatment immediately Do not remove this label CAS 7782-44-7 REV 10/08
GENERAL WARNINGS AND PRECAUTIONS
DO NOT REMOVE THIS PRODUCT LABEL
USE IN ACCORDANCE WITH PRODUCT MSDS
CONTAINER TEMPERATURE SHOULD NOT EXCEED 52 C (125 F)
OXYGEN CERTIFICATE OF ANALYSIS
Lot Number ________ Serial Number_______ Amount ___________________ LBS., GALS., Liters, CU., FT. USP Tests Test ID – ODOR – ASSAY LIMITS OK – NONE – 99.0% RESULT CUSTOMER WITNESSED TEST YES__ NO __ METHOD OF ANALYSIS FOR ASSAY IS THE PARAMAGNETIC OXYGEN ANALYZER MANUFACTURER ______ MODEL #___________ S CUSTOMER WITTNESED TEST YES__ NO__ UPPLIERS SIGNATURE _____________________ DATE____ CUSTOMERS SIGNATURE ________________________ DATE_________ MEDICAL GASES LIQUID OXYGEN, DELIVERY TAG FILLED AND DISTRIBUTED BY THIS VESSEL CONTAINS OXYGEN USP (see reverse side for test results) OXYGEN PRODUCED BY THE AIR LIQUEFACTION PROCESS